Volume Infusion Pump, with Heater And Drug LabProduct Description
seline;">Volume ml/h & Drop d/min Pump, with heater & Drug lab5 year warrantyBuilt-in 500 kinds of drugs, covering the clinical use of the drug dose of 54 units on the library, and could be connect with the PC for edit; export & import.Rate/VTBI,Time/VTBI,Rate/Time,Volume,Drop,Micro,Simple Rate,Programmable,DOSE Weight,Drug Lab,Auto Bolus,Manual Bolus.Open System for 10d/ml,15d/ml,20d/ml,60d/ml(3.4mm - 4.5mm)could add / remove / edit more than 40 kinds tubesVolume Mode:≤±5%,Drop Mode:≤±2% (after calibrate)Automatic or manual calibration of infusion accuracyVolume:0.1ml/h~1200ml/h Purge:600ml/h
Drop:1d/min~400d/min 1~9999 ml or OFF0~9999.9 ml1ml/h~5ml/hAdjustable,Default:1ml/hMaximum 8 steps of different infuse rate / time / VTBIManual Bolus:long Press the Bolus key to infuse and release to stop
Auto Bolus:short press the Bolus key and set the VTBI & RateHigh / Middle / Low, 3level, could off on the menu.200mmHg- 1200mmHg, 20level, livepressure display, mmHg& kPatwo unitsWhen the pressurein the tube goes up, it has the function of early warning1min~30min, The alarm can be set ahead of VTBIchanges the Rate, Time, Dose, VTBI & other important parameters during the infuse workingManual / Auto lock keyboardRecord 20000 infuserecords, 10000 alarmrecords, can be downloaded to the computer to save& querysafety real time self-test function to ensure the pump working properlyDetected by ultrasonicsensor with adjust setting5 level, 50μL ~ 800μL, Infrared sensorto detect the number of drops, monitoring the status in case theempty bottlesBubble, Door open, Finish, Pause timeout,Down Occlusion, Up Occlusion, Lower Battery or damage, Motor error, Incorrect IV Set-type, Pressure test failure, Motor failure, Abnormal droprate, Heater failureand etc. 30 kinds safety monitoring alarm3 colorlighttips:Green for infuse working;Orange forlowlevelalarm(counting working);Redforhigh levelalarm(pump stop).Compliance YY 0709-2009 medical standard, Alarm and key volume level adjustable, with Mute function,High brightness color LCD,Adjustable brightnessRS485port, connect with PC to update / downloadAC100V~240V,50Hz/60Hz,25VANi-MH battery, DC9.6V, 2000mAh (after full charged, could continue work more than 5 hours by 25ml/h rate)Live-timequery battery life andbattery charge status Class I,Type CF, IPX4For round and square pole,Horizontal/ Vertical2.0kg , 130mmx120mmx195mm 5℃~40℃; 20%~90%humidity; 70kPa~106kpaatmospheric For the patients with constant intravenous infusion of drugs