HLC-1PQ04GG (2P/40A/120VAC)Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 40A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard. TypeHLC-1NT00AAC(1P/20A/120VAC) Definite Purpose ContactorStandardIEC60947UL508Rating of CurrentIe 20AFLA: 20AResistive AmpsIth 30ARES: 30ARating of Contacts VoltageUe 240/277V240/277/480/600VACRating of Insulation VoltageUi 660V600VRating of Coil VoltageUs 110VUs: 120VAC 50/60HzMechanical Life1000,000 Cycle1000,000 CycleElectricity life100,000 Cycle250,000 CycleProduct Explanation
1.Product Description
HLC-1NT00AAC Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 277v, Fixed Operating Current To 20A Single-Phase Load Circuit Control,At Present, Widely Applies To The Single-Phase Mechanical Device Main Circuit As Well As The Single-Phase Air-Conditioner Compressor Control.
2 .The Regular Service Conditon And Installs The Condition
a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets
Down The Limiting Value Is -25
b. The Installation Site Elevation Does Not Surpass 2000m
c. The Air Pollution Rank Is 2 Levels
d. Installs The Category Is Ii ;
e. Installment Facing The Gradient Does Not Surpass ±5°
f. Not Remarkable Undulation, Impact And Vibration Place.
3 .Main Technical Parameter
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably
Working, Its Drop Out Voltage In 20% ~ 70%Us
b. Contactor Use Category: Ac-1Ac8a
c. Contactor In With 0.4m Place, Its Noise Below 40db.
4 . Installing Specification And Install Size
a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°
b. Before The Use Should Inspect The Power Terminal And The Contactor
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating
The Breakdown, Behind Check Off May Electrify Tries .Conforms To The Standard
Conforms To National Standard And International Standard1 Conforms ToUL508, IEC60947, GB14048Standard2 Approved ByUL,CUL,TUV,CE,CCC,Safe Certification andISO9001System Certification(SGS)
CCC Certificate Number:2005010309156761
UL Files Number:E251539 HLC-2XT04GGCompany CodeContactorPacking Y : Individual Box Pack - : Factory Bulk Pack2PoleCoil VoltageRating of currentTerminal